Abstract
Aim
To study the outcome of patients with screen-detected breast lesions in whom preoperative core biopsy (CB), or fine needle aspiration cytology (FNAC), or both were suspicious of malignancy or malignant, but the final histology of the excised lesion was benign.
Materials and methods
Thirty-nine patients who fulfilled the above criteria were identified from a prospectively entered database of 192,153 breast screening examinations at the Bedfordshire and Hertfordshire Breast Screening Unit. Thirty-four patients had suspicious or malignant preoperative FNAC and/or CB, and five had FNAC only. Follow-up was mainly by mammograms. Outcome data were collected from hospital case notes and radiology reports.
Results
The median follow-up period was 3 years following excision biopsy. One patient whose excision biopsy histology was atypical ductal hyperplasia developed a mammographically occult carcinoma in the same breast after 24 months. There were no other cancers reported during this time.
Conclusion
The problem of suspicious preoperative needle biopsies with benign excision biopsy is uncommon in the breast screening population. These patients are not at an increased risk of being diagnosed with a carcinoma in the subsequent 3 years and may be discharged back to standard breast screening.